HAIER CEILING CASSETTE SERIES INVERTER

HAIER CEILING CASSETTE SERIES INVERTER

Category: HAIER

Specifications
MODEL
AB35S2S (1.5HP), AB50S2S (2.0HP), AB71S2S (2.5HP), ABH90H (3.0HP), ABH105H (3.5HP), ABH125H (4.0HP), ABH140H (5.0HP)
SERVICES
SELF COLLECT, SELLER DELIVERY, INSTALLATION
Details

1.CERTIFIED AUTHORISED DEALER 

2.FOR DELIVERY KLANG VALLEY AREA WE USE OUR OWN LORRY TRANSPORT.

3.INSTALLATION SERVICE COVERAGE KLANG VALLEY ONLY.

PRODUCT DESCRIPTION


FEATURES

 :HEALTH
- SMART CLEAN, PROVIDING HEALTHIER AIR, HIGH EFFICIENCY FILTER(OPTIONAL), PM2.5 FILTER & STERILIZATION MODULE(OPTIONAL)


 :ENERGY SAVING
- DC FAN MOTOR, NEW HEAT EXCHANGER DESIGN

 
:COMFORT
- FLAP IS CLOSED WHEN AIR COND IS CLOSED, 'SPIRAL PANEL, HIDDEN LED DISPLAY, SUPER BIG INLET GRILLE, ABS MATERIAL PANEL, BRAND-NEW DESIGN FAN

 :COMFORT
- FAN SPEED PROGRAMME, HIGH CEILLING MODE, ROUND WAY AIR SUPPLY, INDIVIDUAL FLAP CONTROL

 :SMART
- INTELLIGENT SENSOR > ABSENCE MODE, AUTOMATIC AIRFLOW DIRECTION

 :CONVENIENCE 

- SQUARE HANGER, DISMANTLING ONLY 1 SCREW, CONVENIENT CLIP, HIGH LIFT-UP DRAIN PUMP

SPECIFICATIONS

AB35S2SC2FA/1U35S1PM1SA

 - Cooling capacity : 12,000 btu/h / 3500 kw
 - Dimension(indoor WxDxH) : 570mm x 570mm x 260mm
 - Controller(standard) : YL-HBS01
 - Panel mode (model): PB-620KB
 - Dimension(WxDxH) : 620mm x 620mm x 60mm
 - Dimension(outdoor WxDxH) : 800mm x 275mm x 553mm

AB50S2SC2FA/1U50S1PJ1SA
 - Cooling capacity : 17,000 btu/h / 5000 kw
 - Dimension(indoor WxDxH) : 570mm x 570mm x 260mm
 - Controller(standard) :YL-HBS01
 - Panel mode (model): PB-620KB
 - Dimension(WxDxH) : 620mm x 620mm x 60mm
 - Dimension(outdoor WxDxH) : 820mm x 338mm x 614mm

AB71S2SG1FA/1U71S1PJ1SA
 - Cooling capacity : 25000 btu/h / 7300 kw
 - Dimension(indoor WxDxH) : 840mm x 840mm x 204mm
 - Controller(standard) :YL-HBS01
 - Panel mode (model): PB-950KB
 - Dimension(WxDxH) : 950mm x 950mm x 50mm
 - Dimension(outdoor WxDxH) : 820mm x 338mm x 614mm

ABH090H1ERG/1U90S1PS2SA
 - Cooling capacity : 30000 btu/h / 9000 kw
 - Dimension(indoor WxDxH) : 840mm x 840mm x 246mm
 - Controller(standard) :YL-HBS01
 - Panel mode (model): PB-950KB
 - Dimension(WxDxH) : 950mm x 950mm x 50mm
 - Dimension(outdoor WxDxH) : 920mm x 372mm x 760mm

ABH105H1ERG/1U105S1PS1SA
 - Cooling capacity : 36000 btu/h / 10500 kw
 - Dimension(indoor WxDxH) : 840mm x 840mm x 246mm
 - Controller(standard) :YL-HBS01
 - Panel mode (model): PB-950KB
 - Dimension(WxDxH) : 950mm x 950mm x 50mm
 - Dimension(outdoor WxDxH) : 950mm x 372mm x 760mm

ABH125K1ERG/1U125S1PN1SB
 - Cooling capacity : 42600 btu/h / 12500 kw
 - Dimension(indoor WxDxH) : 840mm x 840mm x 288mm
 - Controller(standard) :YL-HBS01
 - Panel mode (model): PB-950KB
 - Dimension(WxDxH) : 950mm x 950mm x 50mm
 - Dimension(outdoor WxDxH) : 950mm x 370mm x 965mm

ABH140K1ERG/1U140S1PN1SB
 - Cooling capacity : 48000 btu/h / 14000 kw
 - Dimension(indoor WxDxH) : 840mm x 840mm x 288mm
 - Controller(standard) :YL-HBS01
 - Panel mode (model): PB-950KB
 - Dimension(WxDxH) : 950mm x 950mm x 50mm
 - Dimension(outdoor WxDxH) : 950mm x 370mm x 965mm


[Standard Installation (PWP Installation) includes ]
✅Within 8’ feets Copper Piping with insulation,
✅ within 8' feets 3core control wire from indoor to outdoor unit.
✅Drainage Pipe (UPVC)  15mm x 10 feets
✅Standard MS outdoor Bracket. 
✅1 Month workmanship warranty For Water Leaking and Gas Leaking.

[ Additional Copper  Pipe Charges ]
✅ If you need to place the outdoor unit a bit far from the indoor unit, the additional cost for copper pipe with wire which is more than 10’ feets  as below :
1.0HP   RM 20.00/ft
1.5HP   RM 22.00/ft   
2.0HP   RM 24.00/ft
2.5HP   RM 26.00/ft
3.0HP   RM 28.00/ft
3.5HP   RM 30.00/ft
4.0HP   RM 30.00/ft
5.0HP   RM 30.00/ft

If there is no power point, the installation for the power point charges as below :

[ OPTIONAL ]
✅Add Tapping Wiring Point from nearest socket switches.RM 120.00/unit & RM 160.00/unit (2.0HP  above)

✅Additional On/Off Air cond Switches.                                                     RM60.00/unit 

✅ Wiring Power Point from DB switchboard  to Air cond UnitRM250 - RM350.00/unit (Depends on Site Condition)

[ OPTIONAL ] 
✅Add 1" inch PVC wiring casing= RM10.00/pcs                                          

✅Add 15mm x 10 feets  PVC drain pipe with insulation= RM15.00/pcs.

✅ Add 2”x 3” x 6' feets PVC trunking for covered copper pipe= RM  60.00/pcs

[ Old Unit Dismantling Service ]
- If there is a old or defective air cond need to be dismantled first, before install the new cassette air cond unit, the dismantling service charge is RM120.(Cassette type)
 
[ Before Order please read & Agree to the Standard PWP installation Terms & Conditions. ]

[ Installation Coverage Area ]
- Ampang - Bangi - Cheras - Cyberjaya - Gombak - Kajang - Klang - Kuala Lumpur - Petaling Jaya - Puchong - Putrajaya 
- Selayang - Serdang - Seri Semenyih - Shah Alam 

View more about HAIER CEILING CASSETTE SERIES INVERTER on main site